Metro Group Inc
  • The Metro Group Customer Portal
  • sign in
  • Learn More
  • Safety Data Sheet
  • Home
  • About Us
  • Products & Services
    • New York Tri-State
      • Water Treatment
        • HVAC Water Treatment
          • Reduce Energy Cost With Water Treatment
          • Boiler Water Treatment
          • Cooling Towers
          • Closed Loops
        • Industrial Water Treatment
          • Process & Waste Water
          • Pure Waters
        • Potable/Domestic Water Systems
        • Chemical Feed & Control Equipment
          • Automatic Feed & Control
          • Filter Feeders
          • Installation
        • Pretreatment
          • Sand Filters
          • Water Softners
        • Glycol
        • Services For HVAC Contractors, New Construction & Rehab
        • Remote Monitoring & Control
        • Legionella Water Management
          • Turn-Key Water Management Plans
          • Remediation
          • Secondary Disinfection
        • Specialty Cleanings
          • Heat Exchanger Cleanings
          • Boil Outs
          • Acid Cleanings
          • Tower Cleanings
          • Neutralizers
          • Coil Cleanings For Air Handling Units
          • Ice Machine Cleaning
        • Laboratory Services
        • Endotherm
      • Green Roofs
      • Local Law 97
      • Covid19 Solutions Center
      • Cooling Tower Compliance Overview
      • NYC Cooling Tower Compliance
      • NYS Cooling Tower Compliance
      • DOB/DEP Compliance
      • Emergency Service
      • HVAC Installations
      • HVAC Services & Repairs
      • Fuel Conversions
      • Boiler Services and Repairs
      • Boiler Replacements / Installations
      • Additional Mechanical Room Services
      • Drinking Water Tank Services
      • Drinking Water Services
      • Chimney Services
      • Licensed Electrical Services
      • Plumbing Services
      • Chute Cleaning
    • Central-Upstate New York
      • Water Treatment
        • HVAC Water Treatment
          • Reduce Energy Cost With Water Treatment
          • Boiler Water Treatment
          • Cooling Towers
          • Closed Loops
        • Industrial Water Treatment
          • Process & Waste Water
          • Pure Waters
        • Potable/Domestic Water Systems
        • Chemical Feed & Control Equipment
          • Automatic Feed & Control
          • Filter Feeders
          • Installation
        • Pretreatment
          • Sand Filters
          • Water Softners
        • Glycol
        • Services For HVAC Contractors, New Construction & Rehab
        • Remote Monitoring & Control
        • Legionella Water Management
          • Turn-Key Water Management Plans
          • Remediation
          • Secondary Disinfection
        • Specialty Cleanings
          • Heat Exchanger Cleanings
          • Boil Outs
          • Acid Cleanings
          • Tower Cleanings
          • Neutralizers
          • Coil Cleanings For Air Handling Units
          • Ice Machine Cleaning
        • Laboratory Services
        • Endotherm
      • Safety & Hygiene Products
        • Hand Sanitizer & Spray Disinfectant
        • Dispensers - Wall Mounted, Refillable
        • Janitorial Services
        • Stagnant Water - Hyper - Chlorination For Building Reopening
        • Face Coverings
    • New England
      • Water Treatment
        • HVAC Water Treatment
          • Reduce Energy Cost With Water Treatment
          • Boiler Water Treatment
          • Cooling Towers
          • Closed Loops
        • Industrial Water Treatment
          • Process & Waste Water
          • Pure Waters
        • Potable/Domestic Water Systems
        • Chemical Feed & Control Equipment
          • Automatic Feed & Control
          • Filter Feeders
          • Installation
        • Pretreatment
          • Sand Filters
          • Water Softners
        • Glycol
        • Services For HVAC Contractors, New Construction & Rehab
        • Remote Monitoring & Control
        • Legionella Water Management
          • Turn-Key Water Management Plans
          • Remediation
          • Secondary Disinfection
        • Specialty Cleanings
          • Heat Exchanger Cleanings
          • Boil Outs
          • Acid Cleanings
          • Tower Cleanings
          • Neutralizers
          • Coil Cleanings For Air Handling Units
          • Ice Machine Cleaning
        • Laboratory Services
        • Endotherm
      • Safety & Hygiene Products
        • Hand Sanitizer & Spray Disinfectant
        • Dispensers - Wall Mounted, Refillable
        • Janitorial Services
        • Stagnant Water - Hyper - Chlorination For Building Reopening
        • Face Coverings
    • South East
      • Water Treatment
        • HVAC Water Treatment
          • Reduce Energy Cost With Water Treatment
          • Boiler Water Treatment
          • Cooling Towers
          • Closed Loops
        • Industrial Water Treatment
          • Process & Waste Water
          • Pure Waters
        • Potable/Domestic Water Systems
        • Chemical Feed & Control Equipment
          • Automatic Feed & Control
          • Filter Feeders
          • Installation
        • Pretreatment
          • Sand Filters
          • Water Softners
        • Glycol
        • Services For HVAC Contractors, New Construction & Rehab
        • Remote Monitoring & Control
        • Legionella Water Management
          • Turn-Key Water Management Plans
          • Remediation
          • Secondary Disinfection
        • Specialty Cleanings
          • Heat Exchanger Cleanings
          • Boil Outs
          • Acid Cleanings
          • Tower Cleanings
          • Neutralizers
          • Coil Cleanings For Air Handling Units
          • Ice Machine Cleaning
        • Laboratory Services
        • Endotherm
      • Safety & Hygiene Products
        • Hand Sanitizer & Spray Disinfectant
        • Dispensers - Wall Mounted, Refillable
        • Janitorial Services
        • Stagnant Water - Hyper - Chlorination For Building Reopening
        • Face Coverings
    • Ohio, Virginia, Minnesota
      • Water Treatment
        • HVAC Water Treatment
          • Reduce Energy Cost With Water Treatment
          • Boiler Water Treatment
          • Cooling Towers
          • Closed Loops
        • Industrial Water Treatment
          • Process & Waste Water
          • Pure Waters
        • Potable/Domestic Water Systems
        • Chemical Feed & Control Equipment
          • Automatic Feed & Control
          • Filter Feeders
          • Installation
        • Pretreatment
          • Sand Filters
          • Water Softners
        • Glycol
        • Services For HVAC Contractors, New Construction & Rehab
        • Remote Monitoring & Control
        • Legionella Water Management
          • Turn-Key Water Management Plans
          • Remediation
          • Secondary Disinfection
        • Specialty Cleanings
          • Heat Exchanger Cleanings
          • Boil Outs
          • Acid Cleanings
          • Tower Cleanings
          • Neutralizers
          • Coil Cleanings For Air Handling Units
        • Laboratory Services
        • Endotherm
      • Safety & Hygiene Products
        • Hand Sanitizer & Spray Disinfectant
        • Dispensers - Wall Mounted, Refillable
        • Janitorial Services
        • Stagnant Water - Hyper - Chlorination For Building Reopening
        • Face Coverings
  • Blog
  • Careers
  • Contact Us

Back to Water Treatment

  • Back to Water Treatment

Services & Repairs

Metro Group has the largest fleet of service technicians in the geographies we service. Our Field Technicians are solely focused on service, with no obligations or requirements for selling. All Technicians hold the required licensing for water treatment per local requirements, and receive all required Safety and Chemical Handling training.

Heat Exchanger Cleanings

Heat exchangers are physical plant components, named and used to transfer heat (BTU’s) between interconnected systems in mechanical operations. Designs include shell & tube, or plate & frame. Common heat exchange occurs in water-to-water, steam-to-water, or refrigerant-to-water devices. In the case of process operations, heat may also be transferred into/from a product or process. Depending upon design requirements, they are also defined by the number of “passes” through the exchanger. Over-cycled water will precipitate scale deposits onto hot surfaces as it passes through the heat exchanger. A build-up of deposits can also contain accumulated minerals, excessive corrosion products, bio-film (in a cooling water), or any combination there-of. This causes a dramatic reduction in efficiency and increase in energy costs!

Metro Group can assist with the addition of cleaning chemistry that is circulated through the heat exchanger, cleaning and de-scaling surfaces. This results in decreased energy and repair costs, and increased asset service life.

Heat Exchanger machine that needs Cleaning

    Contact Us / Request a Quote

    © 2025 The Metro Group Inc.
    Metro Group NYC: 50-23 23rd St., Long Island City, NY, 11101, (718) 729-7200

    • Home
    • About Us
    • Blog
    • Careers
    • Contact Us
    • Privacy Policy

    EMERGENCY SERVICE

    (718) 321-8787

    EMERGENCY SERVICE

      For Emergency Service Call:

    (718) 321-8787